Blog
Liposuction Cannulas: Types, Tips, Sizes and Buyer Guide
A liposuction system is made up of a suction source, tubing, a collection canister and the cannula, and surgeons generally agree that the cannula has the biggest effect on how well fat is removed. This guide explains the main types of liposuction cannulas, what the different tips, diameters and lengths are for, how hubs connect to syringes and handles, and what to check before you buy a set.
The three jobs a liposuction cannula does
Cannulas are grouped by the job they do in the procedure. Most clinics need at least one of each type:
| Type | What it does | Typical design |
|---|---|---|
| Infiltration cannula | Delivers tumescent fluid (saline with local anaesthetic and adrenaline) into the fat before suction | Fine shaft with many small holes spread around and along the tip, often in a spiral; connects to a syringe, infiltration handle or tubing |
| Aspiration (suction) cannula | Removes fat by suction from a machine or a syringe | Blunt tip with one, two, three or more openings; sold in a range of diameters and lengths |
| Fat grafting cannula | Harvests fat gently for grafting, then injects it in small amounts | Fine, blunt harvesting cannulas used on a syringe, plus very fine injection cannulas |
Tip and hole styles
The shape and number of openings at the tip decide how aggressively a cannula removes fat:
- Mercedes tip: three holes spaced evenly around the tip. It is the most widely used style because it removes fat evenly in all directions.
- One-hole and two-hole tips: gentler, more controlled removal. Two-hole blunt cannulas are the classic choice for harvesting fat for grafting.
- Multi-port and flared tips: more aggressive patterns used for debulking, breaking up fibrous fat and pre-tunnelling before final sculpting.
- Blunt rounded tip: almost all body and grafting cannulas have a closed blunt end so they glide through fat rather than cut.
Choosing the diameter and length
Diameter controls how much fat moves with each pass. As a rough guide, cannulas around 1.5 to 2 mm are used for fine work and the face, 3 mm for average contouring, and 4 mm and above where a larger volume of fat has to be removed. Fine cannulas are slower but leave a smoother result; large ones are faster but less precise.
Length sets how far the cannula reaches from the incision. Short cannulas work the area close to the entry point, while longer ones reach further. Body cannulas commonly come in lengths around 15, 22 and 30 cm. Longer, thinner cannulas flex more, so wall strength and straightness matter more as length increases.
Cannulas for fat grafting
Fat grafting (fat transfer) uses liposuction cannulas in a gentler way, because the fat has to survive being moved. In the widely used Coleman technique, fat is harvested with a blunt two-hole cannula of about 3 mm on a 10 ml Luer-lock syringe, and the surgeon pulls the plunger back only slightly to keep suction low. Harvesting cannulas are typically 15 or 23 cm long, and the stab incision is made just large enough for a 2 to 3 mm cannula.
After processing, the fat is moved into small 1 ml syringes and placed with very fine blunt injection cannulas in tiny amounts. One practical point for buyers: a longer harvesting cannula gives more reach but puts more twisting force on the syringe tip, so hub quality and a tight Luer-lock fit are important.
Hubs and connections: Luer lock, Toomey and handles
- Luer lock: the standard twist-lock hub. It fits Luer-lock syringes, infiltration handles and tubing, and is the most common choice for fat grafting.
- Toomey: a larger tapered hub that fits 60 ml Toomey syringes. Adapters are available to connect a Toomey syringe to Luer-lock cannulas or syringes.
- Handles for machine suction: aspiration handles connect the cannula to suction tubing. Some sets include a power handle that gives a firmer grip and more control during long cases.
Because surgeons move the cannula vigorously, the hub and its joint to the shaft take a lot of stress. A well-made hub, firmly joined to the shaft, avoids leaks and breakage. Before ordering, check that the hub type matches the syringes and handles you already use.
Our liposuction and fat grafting sets
Liposuction Cannula Set for Fat Transfer

A set of fixed-handle cannulas with different tip styles for liposuction, fat harvesting and fat transfer. View the Liposuction Cannula Set.
Fat Grafting Set with Power Handle and Luer Lock

Liposuction cannulas in several sizes, fat transfer cannulas, a power handle and Luer-lock connectors, for harvesting and grafting in one kit. View the Fat Grafting Set.
Luer Lock Liposuction Kit for Fat Transplantation

One-hole and two-hole cannulas in different sizes, infiltration cannulas, fat transfer cannulas, snap-lock syringes (10, 20 and 50 ml) and a handle, stand and connectors. View the Luer Lock Liposuction Kit.
For body contouring cases that also need skin and tissue instruments, see our abdominoplasty (tummy tuck) instruments set.
Cleaning and care
Cannulas are long, narrow tubes, so fat and blood dry inside them quickly. Good care makes them last for years:
- Flush every cannula with water straight after use, before anything can dry in the lumen.
- Clean the inside with a brush or stylet sized to the bore, and use an ultrasonic cleaner if you have one.
- Check each hole for burrs and each shaft for bends before sterilising; a bent cannula should be replaced.
- Dry fully and sterilise according to your hospital protocol. Read more in how to clean and maintain surgical instruments.
What to check before you buy
- Hub type (Luer lock or Toomey) that matches your syringes and handles.
- A clear size list giving the diameter in mm and the length in cm of every cannula in the set.
- Smooth holes and tips: openings should be deburred and polished inside and out, and the tip fully rounded.
- Straight, rigid shafts with a strong joint to the hub.
- Stainless steel that resists rust, finished with passivation.
- What else is included: handles, connectors, syringes, cleaning brushes and a case.
If you need a diameter, length, hole pattern or hub that is not in a standard set, see how to order a custom surgical instrument.
Frequently asked questions
What is a Mercedes tip cannula?
A cannula with three openings spaced evenly around the tip. It removes fat evenly and is the most common style for general liposuction.
What size cannula is used for fat grafting?
Harvesting is commonly done with a blunt cannula of about 2 to 3 mm on a 10 ml syringe, using gentle suction. The fat is then injected with much finer blunt cannulas in very small amounts.
Should I choose Luer lock or Toomey?
Luer lock is the standard for syringes up to about 60 ml and for most fat grafting work. Toomey hubs fit 60 ml Toomey syringes. Choose the hub that matches the syringes and handles you already use; adapters can join the two systems.
What is the difference between infiltration and aspiration cannulas?
Infiltration cannulas put tumescent fluid into the tissue and have many small holes. Aspiration cannulas take fat out and have fewer, larger openings at a blunt tip.
Are stainless steel cannulas reusable?
Yes. Stainless steel cannulas can be cleaned and autoclaved many times, provided the lumen is cleaned thoroughly after each case and the shafts and holes are inspected before reuse.
Related guides
More guides: see all our surgical instrument buying guides.
Have a question or need a quote? Contact our team.

Chief Executive Officer (CEO)
Zi-Jah Chaudery is the Chief Executive Officer (CEO) at Xtreem Invent, bringing over 20 years of core expertise in the surgical instruments and medical devices manufacturing sector. A visionary leader in international trade and global B2B healthcare exports, he specializes in supply chain management, compliance, and international quality standards. Under his leadership, Xtreem Invent connects premium Pakistani manufacturing with healthcare facilities worldwide.